  • Improving the energy efficiency of the diaphragm pump drive for small-scale power facilities

    The object of the development is an experimental installation with pulsed circulation of the coolant in the main circuit for its use as a hydraulic drive of a diaphragm pump used for pumping liquid in the secondary circuit, which increases the energy efficiency of the pump drive for small-scale energy facilities. An installation with pulsed circulation of the coolant with a diaphragm pump was developed, assembled and tested on the basis of a new design of the shock unit with a cam profile, which makes it possible to create an acceleration of the flow at the pump suction. As a result of the experiment, we obtained the dependence of the volume of the pumped liquid on the frequency of operation of the shock unit.

    Keywords: energy efficiency, diaphragm pump, shock unit, pump drive, cam, fluid flow, fluid pressure, oscillation frequency

  • Adjusting characteristics of the planetary generator of the moment

    In article dependences of resistance are investigated on drove the planetary mechanism from the operating moment on the central wheel. The hypothesis about active and jet components of mechanical resistance is offered in compliance with a method of electromechanical analogies. Results of pilot studies of the adjusting characteristic of the generator of the moment confirming theoretical provisions are presented.